GENERAL
- Compact space-optimised controller for at most 4 drives, with external SMPS, designed for use in applications with limited installation conditions.
- First error safe in accordance with medical requirements and corresponds to the Ecodesign guideline (power consumption <0.5 W in standby).
CUSTOMER BENEFITS
External SMPS | Pluggable version, for global use Reduced variant diversity of cables Quicker reaction to country-specific customer needs Constant load-independent movement speed Increased safety through extra-low voltage in the application as well as integrated short-circuit and overload protection |
Compact housing | Flat compact design Predestined use in space-critical applications |
Increased safety | Compactness offers ideal solution for low floor / low beds for avoiding and reducing the consequences of falling |
Lower maintenance effort | Reduced cycles of normative current leakage measurement thanks to extra-low voltage |
Numerous expansion options | Optional features relating to Lock function Battery and battery charging Power supplies Memory functions |
STANDARD CONFIGURATIONS
Performance data | |
---|---|
Power-on time | 2 – 18 min |
Power-on time | 10 % |
switching cycles max. | 5/min |
Controller | Relay control |
Output voltage | 29-const. V-DC |
Connection options | |
Components | |
Displays | |
Housing colour | Light grey |
RAL | 7035 |
Connection cable | Pluggable: GB plug, grey, coiled, 1960 mm, PVC GB plug, grey, coiled, 2460mm, PVC GB plug with earthing, grey, coiled, 1960 mm, PVC USA plug, grey, smooth, 4000 mm, PVC USA plug with earthing, grey, smooth, 4000 mm, PVC AUS plug, grey, coiled, 1960 mm, PVC AUS plug with earthing, grey, coiled, 1960 mm, PVC JAP plug, grey, smooth, 4000 mm, PVC JAP plug with earthing, grey, smooth, 4000 mm, PVC Shock-proof plug, grey, smooth, 3000 mm, PVC Shock-proof plug, grey, coiled, 1960 mm, PVC Flat plug grey, coiled, 1960 mm, PVC |
Power supply unit | 100-240 V AC – wide range voltage |
SMPS | PD 14 (max.100W) / PD 15 (max.160W) |
EXTRA CONFIGURATIONS
Components | |
---|---|
Controller | Direct control, microprocessor controllers (synchronous controller) |
Connection cable | Power cord with earthing |
Additional data | |
Equipment options | Battery connection Voltage output (29V-DC) e.g. for external lighting Power cord with earthing |
Installation options | Fastening bores Direct fastening to MEGAMAT 2 and MEGAMAT 5 possible (2 mounting clips) |
Performance data | |
Safety | First error safe |
Protection degree | IPX6 |
Connection options | Connections for drives 1-4 Connections for controls: 1-2 |
Protection class | III |
Relative air humidity | 30 – 75 % |
Mains power supply connection | Wide range input voltage: 100 – -240 V AC |
Ambient temperature | 10 – 40 °C |